Eps Timing (Programmable Exposure Common) - JAI AT-030MCL User Manual

Jai digital 3ccd progressive scan rgb color camera
Table of Contents

Advertisement

9.2.1 EPS Timing (Programmable exposure common)

If the shutter mode is set at SM=1(Programmable Exposure (Common),
Minimum Trigger Interval
Smear Less
OFF
ON
On the above table, 511L is FVAL interval on normal continuous mode
1) In partial scan and the vertical binning modes, if programmable exposure
value is larger than 511L, the programmable exposure value is used in this formula.
511L + 5L + (programmable exposure value – 511L) = programmable exposure value + 5L
2) In vertical binning mode, 1L is different from normal scanning. So, the minimum trigger interval will be
different.
Note: If the trigger of Active High is input through 10pin, dummy pulses must be applied
more than one time when the camera is activated.
Mi n . 2 L i n e ~
E x t . T r i g
F V A L
L V A L
S U B
S G
E x p o s u r e
P e r i o d
E E N
X E E N
( Hi rose 12pi n)
D A T A
O U T
D V A L
Note: The value in ( ) is for V-Binning OB.
LVAL Accumulation
LVAL Async
LVAL Sync
AT-030MCL
Mode
Minimum trigger interval
LVAL Sync
511L + 3L
◆Range for programmable exposure: 7L to 511L (Note1)
LVAL Async
Programmable Exposure time + 511L + 3L
LVAL Async
Smearless time(87L) + Programmable exposure time +511L
+ 3L
t 1
t 2
Fr ont OB: ( b)
V-Binning
OFF
ON
OFF
ON
Fig.27. Edge Pre-select.
V - B i n n i n g Of f : 1 L i n e = 9 4 2 C l o c k ( 1 6 . 2 4 u s )
V - B i n n i n g On : 1 L i n e = 1 1 6 4 C l o c k ( 2 0 . 0 7 u s )
FVAL Acti ve
504L (252L)
Eff ecti ve Li nes:( a)
8L(4L)
1 2 3 4 5
t1
7.7μs ~7.7μs + 1L
15.7μs ~15.7μs + 1L
4.2μs ~4.2μs + 1L
8.0μs ~8.0μs + 1L
- 26 -
V-Binning OFF : 1L=16.24μs
V-Binning ON : 1L=20.07μs
Rear OB: ( c)
2L (1L)
t2
5.6L ~6.6L
3.6L ~4.6L
5.6L
3.6L

Advertisement

Table of Contents
loading

Table of Contents