JAI AT-030MCL User Manual page 35

Jai digital 3ccd progressive scan rgb color camera
Table of Contents

Advertisement

 Minimum Trigger interval is shown in the following table.
If the shutter mode is set at Programmable Exposure (common)
Mode
LVAL Async
Note: 1) On the above table, 511L is FVAL interval on normal continuous mode
2) In partial scan mode, the maximum programmable exposure values must be set
within 511L.
If the shutter mode is set at Programmable Exposure (individual)
Mode
LVAL Async
Note: 1) On the above table, 511L is FVAL interval on normal continuous mode
2) In partial scan or vertical binning mode, the exposure time can be set up to
511L.
Note: If the trigger of Active High is input through 10pin, dummy pulses must be applied
more than one time when the camera is activated.
Note: In this mode, if the next trigger is input while the data is read out, the data can
be immediately dumped by the high speed transfer. The minimum trigger interval
should be kept.
AT-030MCL
Minimum trigger interval
Smearless time(87L) + Programmable exposure time +511L + 3L
Minimum trigger interval
Smearless time(87) + Maximum programmable exposure time
among R,G and B channels +511L + 3L
Fig.34 RCT mode
- 33 -

Advertisement

Table of Contents
loading

Table of Contents