9.3.1 PWC timing

V-Binning
OFF
ON

9.3.2 PWC timing - LVAL sync details

LVAL sync reset
Ext. Tri g
FVAL
LVAL
EEN
XEEN
(Hirose 12pi n)
( Exposure)
DATA out
V-Binning
OFF
ON
AT-030MCL
LVAL Accumulation
LVAL Sync
LVAL Async
LVAL Sync
LVAL Async
Fig. 31. Pulse width control.
Exposure Pri od
Del ay of Expos ur e St ar t (B)
t1+1L( M ax)
A
t1(4.2μs) + 1L(max.)
5.6L ~6.6L
t1(8.0μs) + 1L (max)
3.6L~4.6L
Fig.32 Pulse Width Control LVAL SYNC details
t1
16.1μs
16.1μs
24.1μs
24.1μs
LVAL sync reset
Del ay of Expos ur e End (D)
(A)
Data out Del ay (C)
B
- 31 -
t2
5.6L ~ 6.6L
5.6L ~ 6.6L
3.6L ~ 4.6L
3.6L ~ 4.6L
C
16.1μs
13.6L ~14.6L
24.1μs
7.6L~8.6L
D