Section 2 - Installation (Engineer's Procedure); Siting Your Machine; Connecting The Water Supply - Voce PR14037000 Operator's Manual

Table of Contents

Advertisement

Section 2 - Installation (Engineer's Procedure)

Important! It is essential that the personnel responsible for installing and servicing
your machine, understand the following:
1.
The installation and commissioning of your machine should only be carried out by a
trained and authorised service technician.
2.
All water and electrical services must be correctly and safely connected.
3.
All covers must be replaced correctly and securely and your machine left in a safe
condition.

2.1 Siting your Machine

1.
Your machine is only suitable for indoor use, we recommend that it be situated in an
area with an ambient temperature not below 10º C and not exceeding 30º C. Your
machine should be located near the appropriate water and electrical services as
detailed in sub-section 1.1 Specifications.
2.
Prior to placing your machine in its final location, ensure that there is sufficient access
space available via passageways, stairs, lifts, etc.
3.
To ensure adequate ventilation, 100 - 150 mm (4 - 6 inches) clearance must be
allowed between the back of the cabinet and the wall.
4.
Open the door using the key provided. Remove transit packing and installation kit.
Check for visual signs of damage which may have occurred during transit. If your
machine is damaged or any parts are missing, you must contact the supplier
immediately.
5.
Level your machine in both the front-to-back and side-to-side planes by adjusting the
feet. Ensure that the door opens and closes easily and the lock operates correctly.

2.2 Connecting the Water Supply

1.
Your machine should be situated within 1 metre of a drinking water supply from a
rising main, terminating with a W.R.C. approved 15mm compression stop-tap.
N.B. The water supply should comply with both the Statutory Instrument No.1147 -
"Water, England and Wales" and The Water Supply (Water Quality) Regulations 1989.
Water pressure at the stop-tap must be within the limits 2 - 6 Bar (200 Kpa - 600 Kpa).
2.
Freshbrew & B2C Machines: If your VOCE machine is fitted with an Oltre brewer, or
CoEx® B2C brewer, then it must be connected to the water supply via a water filter.
This filter must be of food grade quality and able to remove temporary hardness
(scale), heavy metals (lead, copper, iron, and cadmium), chlorine and any organic
pollutants/discolouration.
Crane Merchandising Systems recommend and supply the
Brita AquaQuell water filter.
5

Hide quick links:

Advertisement

Table of Contents
loading

Related Products for Voce PR14037000

Table of Contents