17.14 To remove the main burner injector.

(See figure 61).
1. Remove the burner (See section 17.13).
2. Remove the burner clamping screw (See figure 61)
3. Unscrew the injector from the burner
4. Refit in the reverse order.

17.15 To remove the appliance from the fireplace.

1. Remove the burner unit (See section 17.7).
2. If the fire retention is as method 1 (See section 9.1 of
this guide), remove the screws.
If the fire retention is as method 2 (See section 9.2 of this guide), slacken the hexagonal
adjusters on the cable retainers and unscrew the thumbscrews to release the cables.
3. Refit as described in the relevant installation sections. Make sure gas soundness,
sealing, spillage test and performance are satisfactory.
©