Advertisement

Quick Links

Model 755
REMOTE CONTROL
INSET LIVE FUEL EFFECT GAS FIRE
Fitted with a
Fascination
(GC No. 32-811-20)
We trust that this guide gives
sufficient details to enable this
appliance to be operated and
maintained satisfactorily. However, if
further information is required, our
Baxi Fires Division Technical
Helpline will be pleased to help.
Telephone 08706 061 065 (National
call rates apply in the United
Kingdom).
In the Republic of Ireland
Telephone 0044 8706 061 065.
This guide is intended to help you care
for your Baxi Fires Division gas fire.
Please read thoroughly before using
and keep for future reference.
This guide to be left with the owner
©
Baxi Heating U.K. Limited 2006.
OWNER GUIDE
fascia
5115012/02

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the 755 and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Baxi Fires Division 755

  • Page 1 In the Republic of Ireland Telephone 0044 8706 061 065. This guide is intended to help you care for your Baxi Fires Division gas fire. Please read thoroughly before using and keep for future reference. This guide to be left with the owner ©...
  • Page 2 Warning: Any person who does any unauthorised act in relation to a copyright work may be liable to criminal prosecution and civil claims for damages. Baxi Fires Division, Erdington, Birmingham B24 9QP www.firesandstoves.co.uk Because our policy is one of constant development and improvement, details may vary slightly from those given in this publication ©...
  • Page 3 BS EN ISO 9001 quality system accepted by the British Standards Institute. The Highest Standards Baxi Fires Division is a member of the Society of British Gas Industries which works to ensure high standards of safety, quality and performance. Careful Installation Baxi Fires Division is a CORGI registered company.
  • Page 4: Table Of Contents

    OWNER GUIDE LIST OF CONTENTS Section Page SAFETY GAS CONSUMPTION APPLIANCE DIMENSIONS OPERATING YOUR FIRE The Oxysafe flame sensing and flue blockage safety system. The remote control handset. Room temperature indicator. To light the fire. To turn off. Burner operation. Locking the remote control handset.
  • Page 5: Safety

    OWNER GUIDE SAFETY IF YOU SMELL GAS DON’T SMOKE. EXTINGUISH ALL NAKED FLAMES. DON’T TURN ELECTRICAL SWITCHES ON OR OFF. TURN OFF THE GAS SUPPLY AT THE METER. OPEN DOORS AND WINDOWS TO GET RID OF THE GAS. IMMEDIATELY CALL THE GAS EMERGENCY SERVICE FROM A NEIGHBOURS PHONE - SEE YOUR LOCAL TELEPHONE DIRECTORY.
  • Page 6: Gas Consumption

    OWNER GUIDE automatically shut off the gas supply to the fire if, for any reason, the flames go out). Do get advice about the suitability of any wall covering near your fire. Soft wall coverings (e.g. embossed vinyl, etc.) which have a raised pattern are easily affected by heat.
  • Page 7: Appliance Dimensions

    OWNER GUIDE APPLIANCE DIMENSIONS Figure 1. Appliance dimensions and clearances OPERATING YOUR FIRE PLEASE NOTE When operating your fire for the first time, some vapours may be given off which may cause a slight odour and could possibly set off any smoke alarms in the immediate vicinity.
  • Page 8: The Remote Control Handset

    OWNER GUIDE The remote control handset. Figure 2. Remote control handset xThe hanset will operate up to a distance of 8 to 10 metres (26 to 33 ft) away from the fire (Depending upon location). If the batteries in the handset become weak it may be necessary to be close to the fire to operate it.
  • Page 9: To Light The Fire

    OWNER GUIDE The display features shown in figure 2 are the only features available on the handset. Light conditions may cause other display features to be seen on the handset. These are NOT available on this model and can be ignored. To light the fire.
  • Page 10: Locking The Remote Control Handset

    OWNER GUIDE hand side of the fire will illuminate to confirm that each signal has been recieved. The fire can NOT be turned OFF by repeatedly pressing the flame decrease button. See the section headed ‘To turn off’ above. Note: i) If the flames repeatedly go out have the fire serviced.
  • Page 11: Fitting Batteries To The Remote Control Handset

    OWNER GUIDE disappear and the remote control handset is now ready for use. Fitting batteries to the remote control handset. The remote control handset is battery powered. To replace the batteries remove the rear battery compartment cover from the remote control handset.
  • Page 12: Cleaning Your Fire

    OWNER GUIDE CLEANING YOUR FIRE To maintain the high performance and quality finish of your fire please follow these guidelines: Before attempting to clean the fire, please remember to turn off the fire and wait for the appliance to cool completely. The fire will retain heat for some time before cleaning can begin.
  • Page 13: Burner

    OWNER GUIDE shown in the ceramic fuel effect installer and owner guide. This should have been left inside or attached to this guide by the installer. Burner. Remove any deposits of soot or other foreign matter from the solid areas of the burner with a dry soft brush.
  • Page 14: Maintenance

    We recommend that all gas appliances and their flues, wherever situated, are checked annually. Servicing. In the United Kingdom servicing can be carried out either by a Baxi Fires Division service engineer or a CORGI registered installer. If you require your fire to be serviced, please contact Baxi Fires Division Service on 08706 090 081 and quote the following details;...
  • Page 15: Useful Telephone Numbers

    OWNER GUIDE USEFUL TELEPHONE NUMBERS General advice about gas and your gas fire: BAXI FIRES DIVISION TECHNICAL HELPLINE 08706 061 065. To report faults or arrange for your fire to be serviced: BAXI FIRES DIVISION SERVICE 08706 090 081. For sales or product information: BAXI FIRES DIVISION SALES 08706 061 067.