convection box. Lower the fascia unit making
sure that the retaining plates locate fully over
the brackets on the convection box (See figure
32).
Swing the bottom control linking bar towards
the centre of the fire to clear the right side of
the fascia. Slide the fascia unit sideways, if
necessary, to align the bottom fixing holes with
those in the convection box. Fix the bottom of
the fascia to the convection box with two
screws (See figure 33).
"Eternal" and "Obsession" only
Supplied with the fire is a self adhesive control
position label. Peel the backing from the label
and place as in figure 34.
12.2.3
"Dream" fascia
Place the fascia against the fireplace front
surface so that the two retaining plates at the
back of the fascia are above the two upper
retaining brackets at the top of the convection
box. Lower the fascia making sure that the rear
retaining plates locate fully into the retaining
brackets on the convection box (See figure 34). If
the inlet pipe runs along the front of the fireplace,
the bottom of the fascia will have to be swung
forwards to clear the pipe while lowering the
casting.
Swing the bottom control linking bar towards the
centre of the fire to clear the fascia. Align the
bottom fixing holes with those in the convection
box. Fix the bottom of the fascia to the convection
box with two screws and washers (See figure 35).
Supplied with the fire is a self adhesive control
position label. Peel the backing from the label and
place as in figure 34.
©
Baxi Heating U.K. Limited 2007.
INSTALLER GUIDE
Page 32
Figure 34. "Dream" fascia top location
Figure 35. "Adorn" fascia
bottom fixing.