3.12 Note that soft wall coverings (e.g. embossed vinyl, etc.) are easily affected by
heat. They may scorch or become discoloured when close to a heating appliance. Please
bear this in mind when installing.
3.13 This appliance must not be installed in any room that contains a bath or shower or
where steam is regularly present.
3.14 An extractor fan may only be used in the same room as this appliance, or in any
area from which ventilation for the appliance is taken, if it does not affect the safe
performance of the appliance. Note the spillage test requirements detailed further on in
this manual. If the fan is likely to affect the appliance, the appliance must not be
installed unless the fan is permanently disconnected.
3.15 Normal adventitious ventilation is usually sufficient to satisfy the ventilation
requirements of this appliance. In GB reference should be made to BS 5871 Part 2 and
in IE reference should be made to the current edition of IS 813 "Domestic Gas
Installations" which makes clear the conditions that must be met to demonstrate that
sufficient ventilation is available.
3.16 Propane gas appliances must not be installed in a room that is built entirely below
ground level (See BS 5871 Part 2).
3.17 If the appliance is to be fitted against a wall with
combustible cladding, the cladding must be removed
from the area covered by the fascia. The cladding must
also not touch the fascia. (See figure 4). We suggest that
the actual fascia is used as a template to mark the area
for combustible cladding removal and that this area is
increased by at least 2mm all round.
3.18 The appliance is fitted with an A.S.D
(Atmosphere sensing device). If the appliance closes
down after a period of operation for no apparent reason,
the consumer should be informed to stop using the
appliance until the installation and appliance have been
thoroughly checked. The A.S.D will shut the appliance
down if an unacceptable amount of harmful products of
combustion accumulate. Under no circumstances should
the A.S.D be altered or bypassed in any way. Only a genuine manufacturers replacement
part should be fitted. The individual A.S.D components are not replaceable.
3.19 A fireguard complying with BS 8423 should be fitted for the protection of young
children, the elderly, or the infirm.
©
Baxi Heating U.K. Limited 2007.
INSTALLER GUIDE
Page 13
Figure 4. Removal of
combustible cladding
(Shown with 'Dream' fascia)

Hide quick links: