We trust that this guide gives
sufficient details to enable this
appliance to be operated and
maintained satisfactorily. However, if
further information is required, our
Baxi Fires Division Technical
Helpline will be pleased to help.
Telephone 08706 061 065 (National
call rates apply in the United
Kingdom).
In the Republic of Ireland
Telephone 0044 8706 061 065.
This guide is intended to help you care
for your Baxi Fires Division gas fire.
Please read thoroughly before using
and keep for future reference.
INSTALLER: Please leave this guide with the
©
Baxi Heating U.K. Limited 2007.
OWNER GUIDE
5115978/02
CONTROL
or
owner

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the 740FS and is the answer not in the manual?

Questions and answers

Summary of Contents for Baxi Fires Division 740FS

  • Page 1 Kingdom). In the Republic of Ireland Telephone 0044 8706 061 065. This guide is intended to help you care for your Baxi Fires Division gas fire. Please read thoroughly before using and keep for future reference. owner INSTALLER: Please leave this guide with the ©...
  • Page 2 the nation’s favourite PLUMBING & HEATING SUPPLIES FREE SHIPPING SECURE PAYMENTS on all orders over £100 to mainland UK shop online with confidence FINANCE AVAILABLE PRICE MATCH spread the cost with low interest rates always get the best deals available we have H U G E R E D U C T I O N S...
  • Page 3 Warning: Any person who does any unauthorised act in relation to a copyright work may be liable to criminal prosecution and civil claims for damages. Baxi Fires Division, Erdington, Birmingham B24 9QP www.firesandstoves.co.uk Because our policy is one of constant development and improvement, details may vary slightly from those...
  • Page 4 BS EN ISO 9001 quality system accepted by the British Standards Institute. The Highest Standards Baxi Fires Division is a member of the Society of British Gas Industries which works to ensure high standards of safety, quality and performance. Careful Installation Baxi Fires Division is a CORGI registered company.
  • Page 5: Table Of Contents

    OWNER GUIDE LIST OF CONTENTS Section Page SAFETY APPLIANCE DIMENSIONS GAS CONSUMPTION OPERATING YOUR FIRE The Oxysafe flame sensing and flue blockage safety system. To light the fire. To turn the fire off. Lighting with a taper. CLEANING YOUR FIRE Metal parts.
  • Page 6: Safety

    OWNER GUIDE SAFETY IF YOU SMELL GAS DON’T SMOKE. EXTINGUISH ALL NAKED FLAMES. DON’T TURN ELECTRICAL SWITCHES ON OR OFF. TURN OFF THE GAS SUPPLY AT THE METER. OPEN DOORS AND WINDOWS TO GET RID OF THE GAS. IMMEDIATELY CALL THE GAS EMERGENCY SERVICE FROM A NEIGHBOURS PHONE - SEE YOUR LOCAL TELEPHONE DIRECTORY.
  • Page 7 OWNER GUIDE VISAGE, DREAM, ETERNAL, DECADENT, OBSESSION AND ICON MODELS ONLY Graph 2. Combustible shelf clearances for VISAGE, DREAM, ETERNAL, DECADENT, OBSESSION and ICON models only. Do provide a suitable guard that complies with BS 8423 for the protection of young children, the elderly and the infirm.
  • Page 8: Appliance Dimensions

    OWNER GUIDE GAS CONSUMPTION Model 740 Has a maximum natural gas input of 6.85kW (Gross) Has a maximum natural gas output of 4.0kW Has a minimum natural gas input of 2.7kW (Gross) Has a minimum natural gas output of 1.34kW Model 740 when converted using kit number 0595211 Has a maximum propane gas input of 6.7kW (Gross) Has a maximum propane gas output of 3.9kW...
  • Page 9 OWNER GUIDE Model Description Adorn Visage Icon Dream Eternal Decadent Obsession Height (mm) Width (mm) Depth into room (mm) Minimum mandatory clearance to combustible surfaces projecting beyond the front of appliance (mm). Recommended clearance to non- combustible surfaces for access purposes (mm).
  • Page 10: Operating Your Fire

    OWNER GUIDE OPERATING YOUR FIRE PLEASE NOTE When operating your fire for the first time, some vapours may be given off which may cause a slight odour and could possibly set off any smoke alarms in the immediate vicinity. These vapours are quite normal with new appliances. They are totally harmless and will disappear after a few hours use.
  • Page 11: To Turn The Fire Off

    OWNER GUIDE When the button reaches the high heat position you will feel a check to its movement. Do not slide the button above the high heat position unless you want to turn the fire off (See note i below). Note i) If the flames go out while setting the control, repeat the full lighting procedure.
  • Page 12: Metal Parts

    OWNER GUIDE Metal parts. Clean the metal parts with a slightly damp cloth and then dry. Do not use abrasive cleaners as these will scratch the fire surface. Ceramic fuel effect pieces and burner compartment walls. This product uses fuel effect pieces and burner compartment walls containing Refractory Ceramic Fibres (RCF), which are man-made vitreous silicate fibres.
  • Page 13: Maintenance

    We recommend that all gas appliances and their flues, wherever situated, are checked annually. Servicing. Servicing can be carried out either by a Baxi Fires Division Service engineer or a CORGI registered installer. If you require your fire to be serviced, please contact Baxi Fires Division Service...