masonry drill. The holes should
be equidistant each side of the
centre line of the fireplace to
ensure that the appliance finishes
centrally in the opening when
tension is applied to the cables.
3. Insert a fibre plug into each
hole. Use the fibre plugs supplied
with this appliance - Never use
plastic plugs instead of the fibre
plugs supplied. Screw the
eyebolts into the plugs. Make
sure that the bolts are secure.
4. Place the convection box unit
close to the fireplace but allow
sufficient access into the fireplace
opening so that the cables can be
threaded through the eyebolts and
returned through the back of the
convection box. If a concealed
connection is being used, insert
the convection box into the
fireplace feeding the supply pipe
through the pierced hole in the
rear grommet.
5. The convection box has two holes at each side of
the convected air opening. Insert one end of each
cable (one cable each side) from the back through the
lower of the two holes and return the end through the
upper of the holes (See figure 21). Give the cables a
pull so that they grip against the convection box
flanges.
©