Troubleshooting - Fire Sense LIP-10A-TGG-LPG-BU User Manual

Pro series
Table of Contents

Advertisement

If you have any questions regarding this product, please call our customer service hotline at 1-866-985-7877,
9a.m. – 6 p.m. (EST), Monday – Friday, or email us at cservice@welltraveled.net.
PROBLEM
Main burner will
not light
Low burner flame
Burner unit

TROUBLESHOOTING

POSSIBLE CAUSE
Gas valve may be off
Fuel tank may be empty
Orifice blocked
Air in supply system
Loose connection
Igniter fails
Gas pressure low with valve
open full
New cylinder or 1st ignition
Cylinder valve on, no gas
flow
AAA Battery behind igniter
button is dead
Pressure is low
Tank is low on fuel
Gas hose is kinked
Control knob at max
Carbon on reflector &
emitter screen
Thick black smoke
15
CORRECTIVE ACTION
Turn gas valve ON
Refill LPG tank
Clean or replace orifice
Purge air from lines. Open gas
lines and depress control knob
for 2-3 mins.
Check all fittings
Use stick lighter to manually
light
Replace cylinder or regulator
Purge air from lines
Replace hose/regulator
assembly
Replace with a new AAA Battery
Replace LPG tank
Fill LPG tank
Check & straighten or replace
Check for obstruction at
passageways and orifices
Clean components as needed
Blockage in burner
assembly--thoroughly clean
burner