Lamp Power

To power the VL1000 lamp, an external ballast or dimmer unit is required depending
on the model.
Incandescent Models
The incandescent versions of the VL1000 ERS luminaire will require an external
dimmer unit for lamp power. A lamp power input cable is provided for connecting to
these units. Install a connector meeting your requirements using the following wire
color code:
Arc Models
An external ballast unit is included with the arc version of the VL1000 ERS luminaire.
The lamp power input cable is already connectorized for use with this unit.
Note: There is no provision for lengthening the cable. The ballast must be placed
within 40 inches (1m) of the luminaire. The Lamp Power Input Cable has conductors
for lamp power and ballast control. It is not compatible with VARI LITE Series 300
lamp runs.
Ballast Unit
02.9 663.00 01 B
I
NSTALLATION
Lamp Power Input Cable
Green/Yellow
* International (Harmonized) Standard
11-Jun-02
: P
D
C
OWER AND
ATA
Wire*
Connection
AC Ground
Blue
AC Neutral
Brown
AC Line
Lamp Cable
40" (1m)
R
ABLING
EQUIREMENTS
VL1000 A/AS
Model Luminaire
2
11