Serial Connections - FLIR F-Series Installation Manual

Hide thumbs Also See for F-Series:
Table of Contents

Advertisement

F-Series Installation Manual

1.12 Serial Connections

The camera supports RS-422 and RS-232 serial communications using common protocols
(Pelco D, Bosch). For configuration settings see paragraph 1.13 "Setting Configuration Dip
Switches" on page 1-8.
Note
The terminal blocks for serial connections will accept a maximum 20 AWG wire size.
1.12.1 Pelco D Commands
The following commands are given with the Pelco ID 01 (the second byte) and the last byte is a
checksum that will change with a changing Pelco ID.
The rest is fixed.
Pelco Command
Zoom out
Zoom in
Aux 1 on
Aux 1 off
Aux 3 on
Aux 3 off
Aux 4 off
Aux 5 off
Aux 6 on
Aux 6 off
Aux 7 on
Aux 7 off
Byte 1
Byte 2
Sync Byte
Address
Desired Pelco
FF
Address
427-0030-00-12, version 110
Command
FF 01 00 40 00 00 41
FF 01 00 20 00 00 21
FF 01 00 09 00 01 0B
FF 01 00 0B 00 01 0D
FF 01 00 09 00 03 0D
FF 01 00 0B 00 03 0F
FF 01 00 0B 00 04 10
FF 01 00 0B 00 05 11
FF 01 00 09 00 06 10
FF 01 00 0B 00 06 12
FF 01 00 09 00 07 11
FF 01 00 0B 00 07 13
Table 1-1: Pelco D AUX Structure
Byte 3
Byte 4
Command 1
Command 2
09/0B =
00
On/Off
March 2010
1—F-Series Camera Installation
F-Series
Zoom in Electronically
Zoom out Electronically
Black Hot
White Hot
Toggle Plateau Values
Toggle AGC Type
IR FFC
Toggle LUT Pallette
Toggle DDE Gain
Toggle AGC ROI
Toggle:MID ITT
Toggle Max Gain
Byte 5
Byte 6
Data 1
Data 2
00
AUX #
Byte 7
Checksum
Hex Sum of
Bytes 2-6
1-7