Power Board Switch Layout and Control.
numbering and on/off settings.
Switch octaves
Baud rate
Protocol
Serial Com
Preset
Hardware/Software
Not Used
Baud Rate: This is the baud rate of the system user serial port. The available values are 2400,
4800, 9600, 19200 kbaud.
Camera Control Protocol: This is the communication protocol selected for the system when
operating over the serial port. The available protocols are Pelco-D and Bosch.
Serial Communication Standard: This determines the electrical interface selected for the user
serial port. The available settings are RS422 and RS232.
Software Override of DIP Switches: This setting determines whether the system will use the
dip switches for configuration or if software settings will override the dip switch settings.
427-0030-00-12, version 110
The tables below defines the switch locations, bit
Table 1-3: Dip Switch Settings—SW102
Settings
Bit 1
OFF
ON
OFF
ON
Bit 3
OFF
ON
OFF
ON
Bit 5
OFF
ON
OFF
ON
Bit 7
OFF
ON
OFF
ON
Bit 9
OFF
ON
Bit 10
X
March 2010
1—F-Series Camera Installation
Description
Bit 2
OFF
2400
OFF
4800
ON
9600
ON
19200
Bit 4
OFF
Pelco-D
OFF
NA
ON
Bosch
ON
NA
Bit 6
OFF
NA
OFF
RS422
ON
RS232
ON
NA
Bit 8
OFF
Section1
OFF
Section2
ON
Section3
ON
Section4
Software select
Hardware select