1.8
Removing the back of the camera
Use a 3 mm hex key to loosen the four captive
screws, exposing the connections at the back
of the camera enclosure. There is a green/
yellow stripe grounding wire connected between
the case and the back cover as shown.
Ensure the camera is properly grounded.
Typical to good grounding practices, the
camera chassis ground should be provided
using the lowest resistance path possible. FLIR
requires using a grounding strap anchored to
the grounding lug on the back plate of the
camera housing and connected to the nearest
earth-grounding point.
Serial Connector
for local control
Not used
Serial Connection
for local control
Not used
Analog Video
427-0030-00-12, version 110
Analog Video
(monitoring output only)
20 AWG MAX
1 2 3 4 5
BNC
RCA
Ethernet
Figure 1-3: F-Series Camera Connections