2000 M50B Engine Data: Remote Heat Exchanger, Reference Condition: Intake-Air Temperature 45 °C - MTU 8 V 2000 M51A Operating Instructions Manual

Mtu 8 v 2000 m50a; 8 v 2000 m50b; 8 v 2000 m51a; 8 v 2000 m51b; 12 v 2000 m50a; 12 v 2000 m50b; 12 v 2000 m51a; 12 v 2000 m51b; 16 v 2000 m50a; 16 v 2000 m50b; 16 v 2000 m51a; 16 v 2000 m51b diesel engines
Hide thumbs Also See for 8 V 2000 M51A:
Table of Contents

Advertisement

3.28 16V 2000 M50B engine data: Remote heat exchanger,
reference condition: Intake-air temperature 45 °C
Explanation
Abbrev.
DL
BL
A
G
R
L
N
-
X
Reference conditions
Engine model
Application group
Intake-air temperature
Raw water inlet temperature
Barometric pressure
Site altitude above sea level
Power-related data (power ratings are net brake power to ISO 3046)
Number of cylinders
Rated engine speed
Continuous power ISO 3046 (10% overload capability, design power DIN
6280, ISO 8528)
General conditions (for maximum power)
Number of cylinders
Intake depression (new filter)
Intake depression, max.
Model related data (basic design)
Number of cylinders
Cylinder arrangement: V angle
Bore
Stroke
Displacement of a cylinder
120 | Technical Data | MW15550/06E 2012-02
Meaning
Reference value: Continuous power
Reference value: Fuel stop power
Design value
Guaranteed value
Guideline value
Limit value, up to which the engine can be operated, without change (e.g. of power set‐
ting)
Not yet defined value
Not applicable
Applicable
16V2000
M50B
3A
°C
45
°C
32
mbar
1000
m
100
16
A
rpm
1800
A
kW
800
16
A
mbar
15
L
mbar
50
16
Degrees
90
mm
130
mm
150
Liters
1.99

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents