MTU 8 V 2000 M51A Operating Instructions Manual page 155

Mtu 8 v 2000 m50a; 8 v 2000 m50b; 8 v 2000 m51a; 8 v 2000 m51b; 12 v 2000 m50a; 12 v 2000 m50b; 12 v 2000 m51a; 12 v 2000 m51b; 16 v 2000 m50a; 16 v 2000 m50b; 16 v 2000 m51a; 16 v 2000 m51b diesel engines
Hide thumbs Also See for 8 V 2000 M51A:
Table of Contents

Advertisement

Display text
Meaning
RL 211+A004-EMU
EMU 1 not recognized on redundant
bus
SS Safety System
Safety system has determined fault on
Failure (EMU)
Engine Monitoring Unit
SS Power Reduction
Safety system has requested power
Active
reduction
SS Emergency Stop
Safety system has triggered emergen‐
cy stop
SS Emergency Stop
Safety system has carried out an ex‐
External
ternally triggered emergency stop
SS P-Coolant
Safety system detects that coolant
pressure is too low
SS P-Lube Oil (ECU) Safety system detects that engine-oil
pressure is too low
SS P-Lube Oil (EMU) Safety system detects that engine-oil
pressure is too low
SS Safety Channel
Safety system fault message
Def. EMU
SS SDAF closed
Safety system reports closed emer‐
gency-air shutoff flaps
SS Safety system
Safety system has caused emergency
stop
stop
SS T-Coolant (ECU)
Safety system has determined that the
coolant temperature is too high
SS T-Coolant (EMU)
Safety system has determined that the
engine coolant temperature is too high
SS T-Lube Oil
Safety system has determined that the
lube oil temperature is too high
Stop Activated (EMU) EMU has triggered automatic stop
command due to limit value violation
Measure
1. Check LOP visually (→ Page 243).
2. Perform LOP test procedures
(→ Page 245).
3. Contact Service.
• Have EMU checked and re‐
placed if required.
Contact Service.
1. Determine cause of automatic
power reduction.
2. Observe further display messages/
alarms.
3. Contact Service.
1. Determine cause of shutdown and
rectify.
2. Observe further display messages/
alarms.
1. Determine cause of shutdown and
rectify.
2. Observe further display messages/
alarms.
Check coolant level and top up if re‐
quired (→ Page 221).
1. Check lube-oil level and top up if
required (→ Page 208).
2. Contact Service.
1. Check lube-oil level and top up if
required (→ Page 208).
2. Contact Service.
Contact Service.
• Have EMU checked and replaced, if
required.
Open emergency-air shutoff flaps.
Determine cause of shutdown and rec‐
tify.
Reduce power.
Reduce power.
Reduce power.
1. Determine cause of shutdown and
rectify.
2. Observe further display messages/
alarms.
MW15550/06E 2012-02 | Troubleshooting | 155

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents