Table 6-1. Personality Ranges/Defaults
PERSONALITY
ACCELeration
DECELeration
MlNimum LEFT speed
MAXimum LEFT speed
MINimum RIGHT speed
MAXimum RIGHT speed
Engine RPM
ACCELeration
DECELeration
MINimum UP speed
MAXimum UP speed
MINimum DOWN speed
MAXimum DOWN speed
Engine RPM
MAXimum speed
Engine RPM
Tower LIFT UP speed
Tower LIFT DOWN speed
Upper LIFT UP
Upper LIFT DOWN
SWING speed
Upper TELEscope speed
Tower TELEscope speed
BASKET ROTATE speed
BASKET LEVEL speed
JIB LIFT speed
– JLG Lift –
SECTION 6 - JLG CONTROL SYSTEM
RANGE
0.1 to 5.0
0.1 to 3.0
0 to 65%
0 to 100%
0 to 65%
0 to 100%
800 to 2900
0.1 to 5.0
0.1 to 3.0
0 to 65%
0 to 100%
0 to 65%
0 to 100%
800 to 2900
0 to 100%
800 to 2900
0 to 100%
0 to 100%
0 to 100%
0 to 100%
0 to 100%
0 to 100%
0 to 100%
0 to 100%
0 to 100%
0 to 100%
DEFAULTS - 600S
1.8
0.7
46
50
46
50
1500
5.0
1.0
46
52
45
52
1800
100
1800
N/A
N/A
60
60
60
70
N/A
50
50
50
4150365-5