JLG 600SJ Service And Maintenance Manual page 265

Table of Contents

Advertisement

FUNCTION
BASKET ROTATE
JIB LIFT
STEER
GROUND MODE
NOTE: Personality settings can be adjusted anywhere within the adjustment range in order to achieve optimum machine performance.
3121202
Table 6-1. Personality Ranges/Defaults
PERSONALITY
ACCELeration
DECELeration
MlNimum LEFT speed
MAXimum LEFT speed
MINimum RIGHT speed
MAXimum RIGHT speed
Engine RPM
ACCELeration
DECELeration
MINimum UP speed
MAXimum UP speed
MINimum DOWN speed
MAXimum DOWN speed
Engine RPM
MAXimum speed
Engine RPM
Tower LIFT UP speed
Tower LIFT DOWN speed
Upper LIFT UP
Upper LIFT DOWN
SWING speed
Upper TELEscope speed
Tower TELEscope speed
BASKET ROTATE speed
BASKET LEVEL speed
JIB LIFT speed
– JLG Lift –
SECTION 6 - JLG CONTROL SYSTEM
RANGE
0.1 to 5.0
0.1 to 3.0
0 to 65%
0 to 100%
0 to 65%
0 to 100%
800 to 2900
0.1 to 5.0
0.1 to 3.0
0 to 65%
0 to 100%
0 to 65%
0 to 100%
800 to 2900
0 to 100%
800 to 2900
0 to 100%
0 to 100%
0 to 100%
0 to 100%
0 to 100%
0 to 100%
0 to 100%
0 to 100%
0 to 100%
0 to 100%
DEFAULTS - 600S
1.8
0.7
46
50
46
50
1500
5.0
1.0
46
52
45
52
1800
100
1800
N/A
N/A
60
60
60
70
N/A
50
50
50
4150365-5
6-19

Advertisement

Table of Contents
loading

This manual is also suitable for:

600s660sj

Table of Contents