1.0

APPLIANCE INFORMATION

Model
Gas Type
Main injectors (2 off)
Pilot Type (MC)
Pilot Type (SC)
Pilot Type (RC)
Max. Gross Heat Input : 5.0 kW
Min. Gross Heat Input : 3.5 kW
Cold Pressure :
Ignition :
Electrode Spark Gap
Weight
Fire box Dimensions (with trim fitted)
Width :
(with standard trim, no spacer)
Height :
(with standard trim, no spacer)
Depth :
(overall-without fender)
Depth :
Flush-fit (from mounting face to rear)
Depth :
Flush-fit (mounting face to rear
with 50mm spacer fitted)
Gas Connection
This appliance is manufactured by :-
BFM Europe Ltd, Trentham Lakes, Stoke-on-Trent, ST4 4TJ
Efficiency Declaration
The efficiency of this appliance has been measured as specified in
BS 7977-1 : 2009 + A1 : 2013 and the result is 78.2%. The gross calorific value of
the fuel has been used for this efficiency calculation.
The test data from which it has been calculated has been certified by BSI.
The efficiency value may be used in the UK Government's Standard Assessment
Procedure (SAP) for energy rating of dwellings.
SECTION 1
INFORMATION AND REQUIREMENTS
FHEC**MN (MC)
FHEC**SN (SC)
FHEC**RN2 (RC)
G20
Size 160 (MC & SC) 190 (RC)
Copreci 21100/141
Copreci 21100/162
ERTA PG-83-10
20.0+/- 1.0mbar
Push Button Piezo (MC models)
1.5V Battery Generator (SC models)
4.5V Battery Generator (RC models)
4.5mm Nominal
26kg (all models)
8mm Compression
(Supplied with fire)
3
FHEC**SP (SC)
G31
Size 86
Copreci 21100/263
or
ERTA PG-82-310C
5.0 kW
3.5 kW
37.0 +/- 1.0mbar
498mm
600mm
250mm
250mm
200mm