APPLIANCE DATA

Main injector (1 off)
Pilot Type.
Type
Max. Gross Heat Input :
Min. Gross Heat Input :
Cold Pressure :
IIgnition :
Electrode Spark Gap :
Weight (Packed) :
Firebox Dimensions (with case fitted)
Width :
Height : (without feet fitted)
Depth :
Height to top of the flue spigot : 425mm (with feet fitted)
Gas Connection :
Efficiency Declaration
The efficiency of this appliance has been measured as specified in
BS 7977-1 : 2009 + A1 : 2013 and the result is 53.9%.
The gross calorific value of the fuel has been used for this efficiency
calculation.
The test data from which it has been calculated has been certified by BSI.
The efficiency value may be used in the UK Government's Standard
Assessment Procedure (SAP) for energy rating of dwellings.
Size 380, Cat 82
Copreci Single Flame
21100 / 178
6.1 kW
1.8 kW
20.0 +/- 1.0 mbar (8.0 +/- 0.4 in w.g.)
Battery Ignition, 1.5V
4.0 mm
22.0kg
710mm
680mm
255mm
8mm compression
(Supplied with fire)