Appliance Data - Flavel FRLCP0MN Installation And Maintenance Instructions Manual

Table of Contents

Advertisement

APPLIANCE DATA

Main injector (1 off)
Bray Elbow size 380, Cat 82
Pilot Type.
Copreci Single Flame
Type
21100 / 178
Max. Gross Heat Input :
6.1 kW
Min. Gross Heat Input :
1.8 kW
Cold Pressure :
20.0 +/- 1.0 mbar (8.0 +/- 0.4 in w.g.)
Ignition :
Rotary piezo, integral to gas valve
Electrode Spark Gap :
4.0 mm
Weight (Packed) :
22.0kg
Firebox Dimensions (with case fitted)
Width :
Height : (without feet fitted)
Depth :
Height to top of the flue spigot : 525mm (with feet fitted)
Gas Connection :
Supplied By www.heating spares.co Tel. 0161 620 6677
710mm
680mm
255mm
8mm compression
(Supplied with fire)