GAS PRESSURE REQUIREMENTS

A MAJOR CAUSE OF OPERATING PROBLEMS WITH GAS APPLIANCES CAN BE IMPROPER GAS PRESSURE!
Problems such as changes in flame color or flame height, pilot or burner outages, intermittent operation,
changes in heat output, excessive burner noise, etc. are nearly always the result of changes in gas pressure
or improper gas pressure at the time of the installation. The most important item to check during the installa-
tion and the first thing to check when problems occur is gas pressure!
Gas supplies normally enter a residence at 1/2 PSI (13" - 15" W.C.) (3. KPA). A regulator is then placed in-
side the residence, which drops this pressure to 7" W.C. (1.8 KPA) (Nat. Gas). This "inches to inches" regula-
tor is of adequate capacity to service the gas appliances (such as dryer, furnace, etc.). If this regulator's
capacity is not sufficient to add the Gas Fireplace, an additional "inches to inches" regulator must be installed
for the Fireplace. EXCEPTION: Some codes allow 2-PSI (1.4KPA) supplies to enter the residence, in which
case "pounds to inches" regulators are used.
The following table provides information on correct gas pressure requirements. Be sure your gas supplier or
plumber carefully follows this table.
GAS PRESSURE REQUIREMENTS
NATURAL GAS
L.P. GAS
TURN GAS VALVE KNOB TO "HIGH" POSITION. GAS PRESSURES MAY VARY PLUS OR MINUS 5%.
NOTE: For High Altitude (Above 5.000 Feet) Some Variations In Air Shutter Settings May Be Required.
Manifold pressure must be taken at the Output Pressure tap and inlet pressure at the Inlet Pressure tap with the burner
operating by a qualified installer (see Figure 2: Gas Pressure Test Port).
OUTLET
PRESSURE
TAP
14
DESIRED
MINIMUM
INLET
INLET
PRESSURE
PRESSURE
7.0" W.C.
5.0" W.C.
(1.12 kPa)
(1.75 kPa)
12.0" W.C.
11" W.C.
(2.75 kPa)
(3.00 kPa)
Figure 2: Gas Pressure Test Ports
INLET
PRESSURE
TAP
MAXIMUM
MANIFOLD
INLET
OUTLET
PRESSURE
PRESSURE
11" W.C.
3.5" W.C.
(2.61 kPa)
(0.87 kPa)
13.0" W.C.
10.0" W.C.
(3.24 kPa)
(2.5 kPa)
AIR SHUTTER
POSITION*
1/16 - 3/16 "
OPEN
1/4" OPEN-MIN.
PRESSURE
REGULATOR