Specifications; Building Permit And Installation Inspection Approval Requirements - Mendota DXV-45 DT4 Installation & Operating Instructions Manual

Gas direct vent fireplace with premium fiber log set combustion system
Hide thumbs Also See for DXV-45 DT4:
Table of Contents

Advertisement

BTUH. (MODEL DXV-45)
BTUH. (MODEL DXV-45)
NOTE: LP CONVERSION KIT #HA-42-00225 OR AA-11-01257 MUST BE PURCHASED SEPARATELY FOR THE DXV-
45 FIREPLACE TO BURN LPG.
MAIN ORIFICE:
REAR BURNER #38 NAT. GAS-#53 L.P. GAS
OVERALL EFFICIENCY
CO-AXIAL DIRECT VENT FLUE
TOTAL WEIGHT
SAFETY
GAS REQUIREMENTS SUPPLY PRESSURE: GAS INLET: 3/8" N.P.T.
NAT. GAS:
L.P. GAS:
ELECTRICAL REQUIREMENTS
ONE OF THE TWO SERVICE OUTLET BOXES INSTALLED IN THIS APPLIANCE. USE EITHER RIGHT SIDE OR LEFT
SIDE SERVICE OUTLET BOX CONNECTION.
APPROVED VENT SYSTEMS: AMERIVENT, DURAVENT, SELKIRK METALBESTOS, SECURITY CHIMNEY
Certified under ANSI Z21.88 (2009) CSA 2-33 (2009) "Vented Gas Fireplace Heaters" not for use
with solid fuel. Approved or bedroom installations and mobile homes. UL307B approved for "mobile
homes, after first sale of home, not for recreational vehicles."
Gas appliances must be tested and certified by a nationally recognized testing and certification agency to American
National Standards Institute - ANSI Gas Appliance Safety Standards. The Mendota Gas DXV Fireplace has been tested
and certified by Intertek Testing Services 8431 Murphy Drive, Middleton, WI
Fireplace Includes A Sealed Combustion System, 9-Piece Ceramic Fiber Log Set & Coals, Firebrick Lined Firebox, Neo-
Ceram Glass, Piezo Igniter, Dual Blowers, Aga Certified Safety System, And Wall Thermostat.
Options: Black, Brass, Classic Brass Or Classic Silver Tone Grill Sets, Black Or 24k Gold "Victoria" & "Tuscany" Filigree
Fronts, Bentley Arched Doors, Andover Arched Doors & 4 Color Overlay Fronts, Prairie Rectangular Doors & 4 Color
Overlay Fronts, Deerfield Front, Wellington Front, Versiheat Remote Forced Air Heat Transfer System, Versiheat II Forced
Air Heat Transfer System, Thermostats, Remote Control Kits.

Building Permit and Installation Inspection Approval Requirements

Failure to provide adequate proof that the installation conforms to all local requirements and the requirements
stated in the Installation and Operating Instructions Manual will void all applicable warranty.
INSTALLER: THESE INSTRUCTIONS ARE TO REMAIN WITH HOMEOWNER.
5

SPECIFICATIONS

MENDOTA, MODEL DXV-45
NAT. GAS
L.P. GAS
EXCEEDS D.O.E. EFFICIENCY REQUIREMENTS (A.F.U.E.) FOR DIRECT VENT
WALL HEATERS
5" INNER, 8" OUTER (DuraVent, AmeriVent, Selkirk, ICC
205 POUNDS
AGA CERTIFIED IPI PILOT SAFETY SYSTEM, ACTIVATED WITH SWITCH, THERMOSTAT
OR REMOTE CONTROL.
7" W.C. (5" W.C. MIN., 11" W.C. MAX.)
12.0" W.C. (12" W.C. MIN., 14" W.C. MAX.)
120 VOLT ON LEFT OR RIGHT SIDE OF APPLIANCE. CONNECT TO ONLY
es and Inserts must comply with all the requirements stated in this Instal-
lation and Operating Instructions Manual.
must also obtain all required Building Permits and Inspection Approval
from the local building inspection department or the local body having ju-
risdiction. In order to validate warranty coverage, Mendota may require
facsimile copies of the Building Permit and Inspection Approval forms.
High Fire - Adjustable to - Low Fire
45,000
40,000
FRONT BURNER #44 NAT. - #3/64 LP
All installations of Mendota Fireplac-
7,500
5,000
The Dealer and/or installer