Note: The DXV45 DT4 ignition system utilizes Transformed DC power for normal ignition functions. In the event of a power
outage, the Battery Pack power is utilized.
IGNITION SYSTEM WIRING SCHEMATIC
VALVE COIL 2
[ORANGE]
VALVE COIL 1
[DARK GREEN]
BLOWER SYSTEM WIRING SCHEMATIC
43

WIRING SCHEMATICS

PILOT LIGHT
ON/OFF
SWITCH
BLACK
GROUND
[YELLOW+GREEN]
IGNITION
MODULE
MAIN
BURNERS
ON/OFF
SWITCH
CONNECT WALL THERMOSTAT TO
THESE TWO CONNECTORS.
[REMOVE MAIN BURNERS ON/OFF
SWITCH FIRST]
DC
RED
TRANSFORMER
BLACK
RED
BATTERY
PACK