Chapter 3 Mchine setting
Function name
Server Setup
(
P.3-17)
EVENT MAIL
Transmit Test
(
P.3-18)
RESET(
P.3-19)
*1. Settable when both of DHCP and AutoIP are [OFF]
*2. Settable only when Auth. is not OFF
*3. Settable only when Auth. is POP before SMTP

Setting a AUTO Power-off

When no operation has been performed for the set time,
the power supply is automatically turned "OFF".
1
Press the
key in LOCAL.
• MACHINE SETUP MENU will be displayed.
2
Press
OFF" , and press the
3
Press
press the
• Set Value : none, 10 to 600min
4
Press the
end the setting.
• If the machine received data from the PC in the
auto-power-off status, the power supply is turned
ON, however, printing operation is not started
automatically.

Setting Take-up unit

Set the operation method when press the ON / OFF
button on the take-up unit.
Also, when the optional tension bar is installed, for setting
whether the tension bar is used or not used.
1
Press the
key in LOCAL.
• MACHINE SETUP MENU will be displayed.
3-12
Set value
SMTP Address
SMTP Port No.
SENDER ADDRESS
POP before
SMTP
Authentication
SMTP
Authentication
OFF
*2
User Name
*2
Pass Word
*3
POP3 Address
*3
APOP
Send the test e-mail.
(MENU)
(twice)
to select "AUTO POWER
key.
to select a set value, and
key.
key several times to
(MENU)
(twice)
Default
Set the SMTP server.
Set the SMTP port number.
Set the e-mail address to be used as the sender mail
address.
Set the SMTP server authentication method (SMTP
authentication).
Set the user name used for the authentication.
Set the password used for the authentication.
Set the POP server.
Set ON/ OFF of APOP.
All setting values are returned to the status
default.
2
Press
to select "TAKE-UP UNIT",
and press the
3
Press
to select "TAKE-UP UNIT" ,
and press the
4
Press
to select a set value, and
press the
key.
• Set Value : ON/ OFF
5
Press
to select "TENSION BAR" ,
and press the
6
Press
to select a set value, and
press the
key.
• Set Value : ON/ OFF
7
Press
to select "TAKE-UP SW" ,
and press the
8
Press
to select a set value, and
press the
key.
• Set Value : Continuance/ Temporary
Continuance :
Switching ON / OFF the winding operation when
pressing the switch each time. (Take-up unit in
operation does not stop until press again ON /
OFF switch.)
Temporary :
Do the winding operation only while holding
down the switch. (When release the switch,
winding operation is stopped. )
9
Press the
end the setting.
Meaning
key.
key.
key.
key.
key several times to