Chapter 2 Basic Operation
Notes when using media press
• When installing the media, align the media's right
edge with the slit line in the platen. Placing the
media rightward of the slit line will make it rise up if
it moves obliquely, and this could cause damage
to the head.
• If a media is misaligned to the right/left more than
fixed position, a error message "MEDIA SET
POSITION R" or is displayed. Set the media
again.
Slit Line
Media

Changing the printing origin

The position of the printing origin can be changed.
Moving the LED pointer to the changing position and
deciding the position.
1
In Local, Press
• It enters into the origin setting mode.
2
Set a light point of the LED pointer to the
changing position by pressing
• Select the carriage and media, moving the point
with [][][][].
3
After determining the origin, press
the
key.
• The printing origin is changed.
2-16
Media
Press
.
.
Typical setting position of printing
origin
The printing origin in the depth direction (X') is positioned
at about 75 mm rearward from the slot for cutting on the
platen. The printing origin in the scanning direction (Y') is
positioned at 15 mm from the right end of the media. The
value in the scanning direction (Y') can be changed using
[MARGIN] in FUNCTION mode. (
This can be changed by using the Jog key.
slot for cutting
approx. 75 mm(X')

Preparing for the Heaters

Changing the Temperature Settings
for the Heaters
You can change/save the temperature settings for the
heaters with "Heater" of the setting mode. (
Here, changing method of the temperature set in the
setting mode is explained.
Set
the
heater
temperature
characteristics of the media you use.
The temperature of the heaters has been set to "OFF" as
default.
Appropriate temperature adjustment can be made
because the temperature can be adjusted even during
printing.
It may take several minutes to tens of minutes for the set
temperature to be reached, depending on the ambient
temperature.
1
Press the
(Heater) in LOCAL.
• The heater temperature adjustment screen will be
displayed.
2
Press
temperature of each heater.
Heater selecting:
Temperature setting: Set with [][]
• The heater starts to get hot.
3
The heating of the heater stops.
• When the heater temperature reaches the set
temperature, the heater icon lights in green.
4
Press the
• The screen returns to LOCAL.
P.3-8)
15 mm
(Y')
P.3-6)
according
to
the
key,and press the
to set the
Select with [][]
key to stop heating.