Terminals VMT6008
5 I
NTERFACES
5.1 I
NTERFACE SETUP
INTERFACE
COM2 (touch
Pos : 25 /D atentec hni k/Schnitts tell en/Spannungs versorgung/Spannungs versorg ung für VMT6008 @ 2\mod_1272360555362_6.doc @ 7683 @
5.2 24 V DC
POWER SUPPLY
The supply voltage is provided via a lead-through terminal including a screw connection
(Phoenix Contact COMBICON MC 1.5/4-STF3.81). (The figure shows the socket inside the
device)
PIN NUMBER
Voltage tolerance
•
Current consumption
The current consumption of this device depends on the equipment version
(e.g. if a heater or WLAN, etc. is installed.)
•
Note:
The power supply can be protected with a slow-blow fuse of up to 4A.
Note:
The typical power consumption of this device is indicated in the "Technical details"
chapter.
Note:
If the case is connected with earth potential at the provided PE contact (e.g. by
connecting the PE contact with the device plug), the electrical insulation is no longer
given. This also applies if the device is installed by using a metal retainer clip.
If you want to have the device electrically insulated from the power supply, you have to
use a method of installation that ensures appropriate insulation.
© ads-tec GmbH • Raiffeisenstr.14 • 70771 Leinfelden-Echterdingen
IRQ
COM1
4
3
screen)
SIGNAL NAME
1
2
3
Ignition contact
4
Input voltage: 24V DC ±20%.
Switch-on current: 7A (10ms)
ADDRESS
3F8h
2F8h
PE
0V DC
24V DC
21