C. Anti-Fog Discharge Control
• The compressor operating frequency is regulated by operation time to prevent fog discharged from indoor until as shown in
the table below.
Operation
Time, T (min)
Model No.
Note:
d. High Pressure Control at Minimum Frequency Control
• When the outdoor air temperature increases to 38.6°C, compressor operating frequency reduces to minimum of 31 Hz.
Compressor operating frequency will resume to normal when outdoor air temperature decreases to 37.8°C.
0
T < 30
30
T < 90
T
90
• Indoor fan is running at Me
-
or below.
• After 420 minutes from the start of operation, the operation timer counting is restarted from "0".
Compressor operating frequency
50Hz
46Hz
43Hz
CU-G95KE
46
70Hz
64Hz
58Hz
CU-G125KE