S-G95KE CU-G95KE / CS-G125KE CU-G125KE
5.
Fan Operation
This operation is enable the fan operation without compressor running. Timer operation is valid for fan operation.
6.
Automatic Operation
When the Automatic mode is selected, the operation mode is decided in accordance to remote control setting temperature,
intake air temperature and outdoor air temperature.
• During judging the operation mode, indoor fan is running at Lo
intake air temperature and outdoor air temperature for 20 seconds. At this time, Power LED is blinking.
After the operation mode is selected, Power LED lights up.
Refer to the examples below, there are 4 determination charts when automatic mode is selected.
(a) When setting temperature of remote control is 18°C and below.
(b) When setting temperature of remote control is 19°C ~ 22°C.
-
speed and outdoor fan at ON in order to sense the indoor