(a) Vertical Airflow Direction Manual
By pressing the remote control vertical airflow direction setting switch, the vane will move to the indicated angle (1, 2, 3, 4, 5)
as shown in the table. When the remote control OFF/ON switch is pressed to stop the unit, the vane will move to the Close
position.
(b) Vertical Airflow Direction Auto
By pressing the vertical airflow direction to AUTO, the vane swings up and down from 7° ~ 36° (during Cooling and Fan) and
3° ~ 33° (during Soft Dry). During Heating operation, the vane angle will shift according to the indoor heat exchanger
temperature as shown below.
B. Horizontal Airflow Direction
(a) Automatic Horizontal Vane angle setting
By setting the horizontal airflow direction to AUTO, the vanes swing left and right from 55° ~ 125° during Cooling, Soft Dry and
Fan operation. During Heating operation, the vane angle will shift according to the indoor heat exchanger temperature as shown
below.
Operation
Heating
Cooling
Anti-dew formation control
Soft Dry
Anti-dew formation control
Fan
Indoor heat exchanger
temperature
Left Vane Position
C
125°
B
90°
A
55°
55° ~ 125°
64° ~ 110°
55° ~ 125°
64° ~ 110°
55° ~ 125°
37
CS-G95KE CU-G95KE / CS-G125KE CU-G125KE
Right Vane Position
125°
90°
55°
55° ~ 125°
64° ~ 110°
55° ~ 125°
64° ~ 110°
55° ~ 125°