S-G95KE CU-G95KE / CS-G125KE CU-G125KE
(b) Manual Horizontal vane angle setting
• By pressing the remote control horizontal airflow direction setting switch, the vane will move to the indicated position (1, 2,
3, 4, 5, 6, 7) as shown in the table.
• Horizontal van angle position
1
Operation
Heating
Cooling
Anti-dew Formation Control
Soft
Dry
Anti-dew Formation Control
Fan
(c) Wie / Spot Airflow Setting
By pressing the remote control WIDE/SPOT switch, the vane will move to position 3 while WIDE and position 2 while SPOT.
For All
Operations
10.
Quiet Operation
The purpose of this control is to reduce indoor operating noise. Indoor fan speed is set to Lo
occur.
• Indoor fan speed is set at Low
• Indoor heat exchanger temperature rises to 17°C or above
• Compressor operates for 5 minutes or more
• Operation frequency is less than 33Hz (CU-G95KE) or 36Hz (CU-G125KE)
This control is cancelled when one of the following conditions occurs.
• Indoor fan speed is not set at Low
• Indoor heat exchanger temperature is decreased to 13°C or below
• Compressor operation frequency is more than 33Hz (CU-G95KE) or 36Hz (CU-G125KE)
2
3
(Left vane position)
1
2
3
90°
125°
55°
90°
125°
55°
90°
110°
64°
90°
125°
55°
90°
110°
64°
90°
125°
55°
WIDE
SPOT
3
2
4
5
4
5
6
7
1
55°
55°
90°
125°
90°
55°
55°
90°
125°
90°
64°
64°
90°
110°
90°
55°
55°
90°
125°
90°
64°
64°
90°
110°
90°
55°
55°
90°
125°
90°
38
6
7
(Right vane position)
2
3
4
5
6
125°
55°
125°
90°
55°
125°
55°
125°
90°
55°
110°
64°
110°
90°
64°
125°
55°
125°
90°
55°
110°
64°
110°
90°
64°
125°
55°
125°
90°
55°
-
when the following conditions
7
55°
55°
64°
55°
64°
55°