S-G95KE CU-G95KE / CS-G125KE CU-G125KE
How to use electronic circuit diagram
TIMER TABLE <INDOOR>
4 Way Valve abnormality
Outdoor air temp. for Hz No. decision
Anti-dew formation control
Anti-freezing control
Themo OFF delay
Low pressure control (gas leakage) compressor OFF time
Time delay safety control
Outdoor timer status shift time
Intake air temp. sampling time
Auto mode judgement sampling time
24 hours ON / OFF timer
Heating SSHi fan speed shift
Cooling SHi fan speed shift
Hot start forced completion
Outdoor timer status shift time
Auto mode judgement interval
Sleep mode timer shift
After Hot start / Deice
Name
Time
4 min.
30 min.
20 min.
6 min.
3 min.
3 min.
2 min. 58 sec.
30 sec.
60 sec.
20 sec.
1 hr.
120 min.
30 min.
4 min.
30 min.
90 min.
180 min.
4200 min.
30 min.
2 min.
110
Test mode
(When test point
Short-circuited)
2.4 sec.
0 sec.
0 sec.
0 sec.
0 sec.
0 sec.
0 sec.
0 sec.
0 sec.
6 sec.
1 hour → 1 min.
12 sec.
3 sec.
0 sec.
3 sec.
9 sec.
18 sec.
42 sec.
3 sec.
1 hour → 6 sec.
12 sec.