Panasonic CS-G95KE CU-G95KE Service Manual page 22

Panasonic cs-g95ke cu-g95ke/ cs-g125ke cu-g125ke room air conditioner
Hide thumbs Also See for CS-G95KE CU-G95KE:
Table of Contents

Advertisement

S-G95KE CU-G95KE / CS-G125KE CU-G125KE
B. Deodorizing Control
• This control is available during automatic fan speed for Cooling and Soft Dry Operation. It is not available during anti-
freezing control.
• When the compressor is in operation, the deodorizing status starts from 1 → 2.
• When the compressor stops operation, the deodorizing status starts from 3 → 4 → 5.
• If the compressor stops operation, indoor fan stops for 330 seconds.
C. Sensible Heat Control
• This control is to improve the feeling in high fan speed and low operation frequency. When the operation frequency is less
than 33Hz (CU-G95KE) or 36Hz (CU-G125KE), the fan speed will reduce. When the operation frequency is increased to
40Hz (CU-C95KE) or 49Hz (CU-C125KE) continuously for 5 minutes, the fan speed will resume to normal condition. (During
Cooling operation).
22

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Cs-g125ke cu-g125ke

Table of Contents