(c) Cooling Operation at SHi Speed
During Cooling operation, Indoor Fan speed is set at SHi when the following conditions occur:
• Outside air temperature is 30°C or above
• Compressor operates at 50Hz (CU-G95KE) or 70Hz (CU-G125KE) and above
• Remote control setting fan speed is High
• Indoor intake air temperature is 24°C or above
• Remote control setting temperature is 16°C
• Within 30 minutes after start of operation
(d) Heating Operation at SSHi Speed
During Heating operation, Indoor Fan speed is set at SSHi when the following conditions occur:
• Heating operation for 2 hours or more
• When remote control setting fan speed is High
• Indoor intake air temperature is 17°C or above and less than 23°C
• Outdoor air temperature is below 4°C
• Remote control setting temperature is 30°C
• Compressor operates at 71Hz (CU-G95KE) or 90Hz (CU-G125KE) and above
• Airflow Direction is set at Manual
8.
Outdoor Fan Control
• Outdoor fan motor is controlled with 1 speed only. Fan is in operation when the compressor starts operation and stops 30
seconds after compressor stops operation.