Developer drive coupling assembly removal
1.
Remove the left side cover. See
2.
Carefully place the MFP on its right side. Protect the cover from marring.
3.
Remove four screws (A) in the gear train metal cover.
4.
Remove the gear train metal cover.
5.
Remove the conical spring (B) and the developer drive coupling assembly (C).
"Left side cover removal" on page
4-4.
Repair information
7011-2xx