527 – TD EngineSpd. Sensor Deviation
Cause
Maximum deviation of speed
sensors
528 – SD Engine Speed 3rd Sensor
Cause
Redundant crankshaft sensor
faulty; Short circuit or wire
break
576 – AL ESCM Override
Cause
Violation of corrected MCR or
DBR/MCR curve. Engine
overload!
577 – SD T-Lube Oil Pan
Cause
Temperature sensor in oil pan
defective; Short circuit or wire
break
582 – AL Emergency Stop Failed
Cause
This alarm occurs if the engine
fails to come to a standstill
within a specified (by
parametrization) a period of time
after the emergency stop signal
was output.
588 – SD P-Oil Refill Pump
Cause
Pressure sensor faulty; Short
circuit or wire break
ZKP-Number: 10.480.093
Corrective action
1. Check cabling of speed sensors. Observe additional messages.
2. Contact Service.
ZKP-Number: 12.500.102
Corrective action
u Check sensor and cabling, replace as necessary.
ZKP-Number: 11.075.083
Corrective action
u Reduce power.
ZKP-Number: 10.137.900
Corrective action
u Check sensor and cabling, replace as necessary.
ZKP-Number: 11.005.006
Corrective action
u The delay between the emergency stop signal and this alarm
signal is set in parameter 1.1005.4.
ZKP-Number: 10.159.910
Corrective action
u Check sensor and cabling, replace as necessary.
MS150048/04E 2013-07 | Troubleshooting | 107