359 – AL Open Load Cylinder B9
Cause
Disruption fault in injector
cabling to cylinder B9. Result:
Misfiring
360 – AL Open Load Cylinder B10
Cause
Disruption fault in injector
cabling to cylinder B10. Result:
Misfiring
361 – AL Power Stage Low
Cause
Internal electronic fault
(electronics possibly faulty). If
bit "1.1020.021" (Power Stage
Failure: Stop Engine) is set,
engine will be shut down as
additional measure.
362 – AL Power Stage High
Cause
Internal electronic fault
(electronics possibly faulty). If
bit "1.1020.021" (Power Stage
Failure: Stop Engine) is set,
engine will be shut down as
additional measure.
363 – AL Stop Power Stage
Cause
Internal electronic fault
(electronics possibly faulty). If
bit "1.1020.021" (Power Stage
Failure: Stop Engine) is set,
engine will be shut down as
additional measure.
100 | Troubleshooting | MS150048/04E 2013-07
ZKP-Number: 18.004.558
Corrective action
1. Check continuity of injector cabling or exclude open load in
solenoid valve circuit (e.g. by injector replacement)
2. Error clearance: After each working cycle.
ZKP-Number: 18.004.559
Corrective action
1. Check continuity of injector cabling or exclude open load in
solenoid valve circuit (e.g. by injector replacement)
2. Error clearance: After each working cycle.
ZKP-Number: 18.004.496
Corrective action
u Start ITS. If the ITS diagnosis result is "electronics OK", note
further fault messages (e.g. cabling faults).
ZKP-Number: 18.004.497
Corrective action
u Start ITS. If the ITS diagnosis result is "electronics OK", note
further fault messages (e.g. cabling faults).
ZKP-Number: 18.004.560
Corrective action
u Start ITS. If the ITS diagnosis result is "electronics OK", note
further fault messages (e.g. cabling faults).