102. Program Lock
1) DISABLE
Setting
Value
2) ENABLE
103. Low Feed Set
1) DISABLE
Setting
Value
2) ENABLE
104. Clmp Ref POS
1) Ref_UP
Setting
Value
2) Ref_DOWN
160
This function locks the program mode of the main menu.
Disabled (Default)
[Contents] When the function is disabled, the usage of program mode is as same as before.
In use
[Contents] When the function is enabled, it is impossible to enter the program mode.
When sewing is completed, the lower feed plate is automatically removed.
Disabled (Default)
[Contents] When the function is disabled, the usage of program mode is as same as before.
In use
[Contents] When the function is enabled, the lower feed plate is automatically removed.
This function sets the basic position of the clamp.
Disabled (Default)
[Contents] When the function is disabled, the usage of program mode is as same as before.
In use
[Contents] For use, the clamp s pneumatic lines A and B shall be exchanged before connection.