055. FF Duty
40~48%
Setting
Value
056. TT Duty
30~80%
Setting
Value
057. TR Duty
30~80%
Setting
Value
058. WP Duty
30~80%
Setting
Value
It is to set the maintenance capacity of feed plate solenoid.
It is to set the amount of maintenance current permitted to solenoid.
(Factory installed condition 80%), (SPS/A/B-1306, 1507 43)
[Contents] In case of feed plate used with electronic solenoid, it sets the maintenance
power that presses the feed plate by permitting the adjusted current through
duty to the solenoid.
[Reference] In the area with low voltage input, raise the duty value of failure by 5%.
It is to set the maintenance capacity of the thread trimming solenoid.
It is to set the amount of maintenance current permitted to solenoid.
(Factory installed condition : 50%)
[Contents] In case of thread trimming used with electronic solenoid, it sets the power that
keeps trimming operation by permitting the adjusted current through duty to the
solenoid.
It is to set the maintenance capacity of the thread retaining solenoid.
It is to set the amount of maintenance current permitted to solenoid.
(Factory installed condition : 50%)
[Contents] In case of thread retaining used with electronic solenoid, it sets the power that
keeps thread retaining operation by permitting the adjusted current through duty
to the solenoid.
It is to set the maintenance capacity of the wiper solenoid.
It is to set the amount of maintenance current permitted to solenoid.
(Factory installed condition : 50%)
[Contents] In case of wiper used with electronic solenoid, it sets the power that keeps
wiper operation by permitting the adjusted current through duty to the solenoid.