4080-001
Aligning the Cartridges
1. Enter Diagnostics Mode.
2. Select Align Cartridges.
3. Press <MENU> to select the test.
4. Press Select
•
Horizontal Align
•
Vertical Align
•
Bi-di Black Align
•
Bi-di Color Align
5. Test (A) Alignment = XX* - The alignment can be changed by
pressing <MENU> to change the setting.
6. Press SELECT to save the setting.
7. Once any changes have been made, a test page can be printed
showing the changes by selecting Print Align Page.
8. Use the test page to check each alignment, A-D.
9. If changes are necessary repeat step 5.
Cleaning the Printheads
1. Enter Diagnostics Mode.
2. Select Hardware Test.
3. Press <MENU> to go to "Clean Heads".
4. Press Select. The nozzle test pattern test page prints.
Paper Lifters Operation Theory
As the carrier applies pressure against the clutch lever, located in
the gear box assembly, the left and right paper lifters engage,
positioning the media into the printer. Media is then pulled through
the printer by the combination of torque action between the paper
feed motor and the large feed roller, and friction between the paper
feed motor and the media.
3-2
Service Manual