Power Supply; User Interface - Datalogic DS6300 Reference Manual

Hide thumbs Also See for DS6300:
Table of Contents

Advertisement

INSTALLATION

2.3.6 Power Supply

The supply voltage of a single scanner must be between 15 and 30 VDC.
Datalogic strongly recommends a minimum 24 VDC supply voltage when using a
master/slave configuration.
The power consumption of the different DS6300 models is slightly different.
In particular, when connecting several DS6300 readers in a master/slave connection, the
typical power consumption for each scanner is 15 W. There is a power peak of about
20 W lasting 5..10 seconds caused by the motor starting.
A security system allows the laser to activate only once the motor has reached the correct
rotational speed; consequently, the laser beam is generated after a slight delay from the
power on of the scanner.
Note that GND is internally connected to chassis. The cable shield is also connected to
pin 1 - CHASSIS.

2.4 USER INTERFACE

9-pin male connector
Pin
2
3
5
7
8
DS6300
9/13
23/25
1
Chassis
Figure 44 – Power Supply Using the 25/26-pin Connector
RS232 PC-side connections
5
1
6
9
Name
RX
TX
GND
RTS
CTS
USER INTERFACE
VS
V+ (15 – 30 Vdc)
GND
V- (Ground)
CHASSIS
Earth Ground
1
14
25-pin male connector
Pin
3
2
7
4
5
2
13
25
Name
RX
TX
GND
RTS
CTS
33

Advertisement

Table of Contents
loading

Table of Contents