Auxiliary Interface - Datalogic DS6300 Reference Manual

Hide thumbs Also See for DS6300:
Table of Contents

Advertisement

2

Auxiliary Interface

The auxiliary serial interface is equipped with RS232 full-duplex interface connections. The
interface type is exclusive and is selectable through the Genius™ configuration program. The
overall maximum cable length should not exceed 15 m (50 ft).
The following pins of the 25-pin and 26-pin connector are used for RS232 full-duplex
interface connection:
20
Pin
Name
20
RXAUX
21
TXAUX
23
SGND AUX
DS6300
20
21
23
1
Figure 22 - RS232 Auxiliary Interface Connections
Function
Receive data
Transmit data
Auxiliary signal ground
USER INTERFACE
RXAUX
TXD
TXAUX
RXD
GNDAUX
GND
CHASSIS
Earth
Ground
DS6300

Advertisement

Table of Contents
loading