Datalogic DS6300 Reference Manual page 32

Hide thumbs Also See for DS6300:
Table of Contents

Advertisement

2
The table below gives the pinout of the C-BOX 100 terminal block connectors. Use this
pinout when the DS6300 reader is connected in a network by means of the
C-BOX 100:
1, 3, 5
VS
2, 4, 6
GND
7, 8
EARTH GROUND
20, 40
Reserved
27
EXT TRIG/PS A (polarity insensitive) for PS
28
EXT TRIG/PS B (polarity insensitive) for PS
29
IN 2/ENC A (polarity insensitive) for Encoder
30
IN 2/ENC B (polarity insensitive) for Encoder
31, 33
IN 3A (polarity insensitive)
32, 34
IN 4A (polarity insensitive)
36
IN 3B/IN 4B Reference (polarity insensitive)
21
OUT 1+
22
OUT 1-
23
OUT 2+
24
OUT 2-
25
OUT 3A (polarity insensitive)
26
OUT 3B (polarity insensitive)
35
TX AUX
37
RX AUX
38, 39
GND
Pin
RS232
11, 15
TX232
12, 16
RTS232
17
RX232
18
CTS232
SGND Main Isolated
10, 14, 19
9, 13
16
C-BOX 100 Terminal Block Connectors
Power
Inputs
Outputs
Auxiliary Interface
Main Interface
RS485
Full-Duplex
TX485+
TX485-
RX485+
RX485-
SGND Main Isolated
RS485 Cable Shield
RS485
Half-Duplex
RTX485+
RTX485-
SGND Main Isolated
RS485 Cable Shield
DS6300
20 mA C.L.
(with INT-30 only)
see INT-30
instructions

Advertisement

Table of Contents
loading

Table of Contents