Datalogic DS6300 Reference Manual page 44

Hide thumbs Also See for DS6300:
Table of Contents

Advertisement

2
The diagram below represents the termination of a DS6300-XXX-010 working as master by
means of the BTK-6000 terminator.
The diagram below represents the termination of a DS6300-XXX-010 working as slave by
means of the BTK-6000 terminator.
The diagram below represents the connection between a DS6300 Fieldbus model, which
always works as master, and a DS6300-XXX-010 working as a slave reader.
Figure 37 – DS6300-XXX-010 Master/Slave Lonworks Connection
28
Master
VS
9
VS_I/O
6
LON A
7
LON B
8
GND
2
REF_I/O
3
= male connector
= female connector
Figure 35 – DS6300-XXX-010 Master Termination
Slave
LON A
7
LON B
8
= male connector
= female connector
Figure 36 – DS6300-XXX-010 Slave Termination
Fieldbus Master
VS_I/O
4
5
REF_I/O
3
LON A
7
T
LON B
8
CHASSIS
1
VS
9
GND
2
= male connector
= female connector
BTK-6000 Female Side
9
6
7
T
8
2
3
BTK-6000 Male Side
7
T
8
Slave
4
5
3
7
8
CHASSIS
1
AWG 16
9
2
AWG 16
DS6300

Advertisement

Table of Contents
loading

Table of Contents