Positioning The Scanner - Datalogic DS6300 Reference Manual

Hide thumbs Also See for DS6300:
Table of Contents

Advertisement

2
How To Build A Simple Interface Test Cable:
The following wiring diagram shows a simple test cable including power, external
(push-button) trigger and PC RS232 COM port connections.
DS6300

2.5 POSITIONING THE SCANNER

The DS6300 reader is able to decode moving barcode labels at a variety of angles, however
significant angular distortion may degrade reading performance.
When mounting DS6300 take into consideration these three ideal label position angles:
Pitch 0°, Skew 10° to 30° and Tilt 0°.
Follow the suggestions for the best orientation:
The Pitch angle is represented by the value P in Figure 45. Position the reader in order to
minimize the Pitch angle.
34
25-pin D-sub female
TXAUX
21
20
RXAUX
GND
23
13
VS
25
GND
9
VS
18
EXT TRIG A
19
EXT TRIG B
Trigger
Test Cable for DS6300
Figure 45 - "Pitch" Angle
9-pin D-sub female
2
3
5
Power Supply
VS (15 – 30 VDC)
Power GND
P
DS6300
RX
PC
TX
GND

Advertisement

Table of Contents
loading

Table of Contents