Motorola MW810 Installation Manual page 23

Mobile workstation series
Hide thumbs Also See for MW810:
Table of Contents

Advertisement

• Long Display Signal Cables (longer than 3 Meters, 10 feet) should be routed
!
inside protective ducts to avoid damage.
• The MW810 Mobile Workstation Display is shipped with a protective film that
Caution
covers the touch screen. Once installation is completed, the protective film must
be removed to avoid damage to the touch screen during operation.
Connection to Standard Personal Computer
The laptop to MW810, 12.1" Display Signal Cable (optional DVI, P.N FKN8454 or RGB,
P.N FKN8449 cable) enables you to interface the MW810, 12.1" Display to any laptop or
personal computer. For cable connection, refer to Figure 9.
Standard Laptop or Personal Computer
RGB or DVI Connector
USB Connector
(male type)
Speaker Jack
Figure 9
Connection of MW810, 12.1" Display to Laptop or Standard Personal Computer
The following table describes the connectors of the MW810, 12.1" Display to Laptop or
Standard Personal Computer.
Connector
RGB or DVI
USB 2.0
Speaker Jack
On /Off Signal Wire
(Green wire)
On / Off Signal Wire (Green wire)
Description
RGB or DVI signals from the personal computer to display.
USB communication with the personal computer.
This communication enables operation of the function buttons,
emergency button and Power button for turning the workstation
On/Off.
Audio signal from the personal computer to display speaker.
On /Off Signal Wire (active low 0V) is used as a trigger signal
for activating the display when docking the ML910 or ML900
laptop computers.
Laptop to 12.1" MW810 Display Signal Cable
Installation
13

Advertisement

Table of Contents
loading

This manual is also suitable for:

F5208

Table of Contents