5.2 Electric Lock Connection

5.2.1 Door Lock Controlled with Internal Power

Note:
1.
Electronic lock of Power-on-to-unlock type should be used.
2.
The door lock is limited to 12V, and holding current must be less than 250mA.
3.
The door lock control is not timed from Exit Button(EB).
4.
The
Unlock Mode
connect one lock
Connect one lock
Jumper position in
S1
BUS
PL
+
EB
*

5.2.2 Door Lock Controlled with Dry Contact

Note:
1.
The external power supply must be used according to the lock.
2.
The jumper must be taken off before connecting.
3.
Setup the
• Power-on-to-unlock type:Unlock Mode=0 (by default)
• Power-off-to-unlock type:Unlock Mode=1
Parameter of Monitor must be set to 0 (by default).
1-2
S2
S-
+
LOCK
of Monitor for different lock types.
Unlock Mode
connect two locks
Connect two locks
Jumper position in
1-2
BUS
PL
S1+
EB
2
nd
*
EB
1
ST
*
S2+
S-
2
LOCK
1
LOCK
nd
ST