Toro Workman MD Service Manual page 109

Hide thumbs Also See for Workman MD:
Table of Contents

Advertisement

1. Governor shaft (Workman MD)
NOTE: When installing case (RH) to the case (LH) on
Workman MD, hold governor shaft so the ball bearing
will not drop off. Keep the gasket sealing surfaces of the
cases as horizontal to each other as possible. If the seal-
ing surfaces do not join to each other, tap the case lightly
with a plastic hammer.
1. Axle bracket
E. Position axle bracket to each axle case. Secure
axle bracket to each axle case with flange bolts.
Torque bolts from 25 to 31 ft- -lb (34 to 42 N- -m).
Workman MD/MDX
1
15 to 18 ft- -lb
2
(21 to 25 N- -m)
Figure 75
2. Bolt
C. Install case (RH) so each shaft fits properly into
the case.
D. Secure case (RH) to case (LH) with bolts. Torque
bolts from 15 to 18 ft- -lb (21 to 25 N- -m).
25 to 31 ft- -lb
(34 to 42 N- -m)
1
Figure 76
2. Flange bolt
Page 5 - - 47
2
Drive Train