15.Secure A1 and A2 terminals to commutator end
head with fiber washer, flat washer, lock washer and nut
on each terminal. Torque nuts from 40 to 50 in- -lb (4.6
to 5.6 N- -m).
16.Secure commutator end head assembly to frame
housing with two (2) screws. Use marks placed on end
head and housing to properly orientate head. Torque
screws from 49 to 66 in- -lb (5.6 to 7.4 N- -m).
17.Position the starter/generator on the commutator
end head and support the assembly to prevent damage
to the terminals in the end head.
Workman MD/MDX
Page 6 - - 31
Rev. B
Figure 43
Figure 44
Figure 45
Electrical System