7. On Workman MD, disassemble governor fork and
shaft.
1. Screw (2 used)
2. Stopper
IMPORTANT: Make sure to not damage the screw
heads when removing screws. Each screw is se-
cured with an adhesive.
1. Governor shaft
2. Boss
IMPORTANT: Make sure to not damage the oil seal
when removing the governor shaft from the gover-
nor boss.
Workman MD/MDX
4
Figure 48
3
Figure 49
Page 5 - - 33
3
2
1
3. Governor fork
4. Case (RH)
A. Remove both screws and washers securing the
stopper and governor fork to the case (RH). Remove
stopper and fork from the case.
1
2
3. Oil seal
B. Carefully pull governor shaft from the boss.
C. Replace oil seal if cracked, nicked or distorted
such that it would not hold a proper seal.